ADS瞬时仿真时出现ERROR

录入:mweda    点击:
用ADS进行瞬时仿真时,出现下述的错误,这是我copy的仿真文件叙述Warning detected by HPEESOFSIM during DC analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X6218.L1.i' and `X5906.L1.i').
Error detected by HPEESOFSIM during DC analysis `Tran1'.
Circuit as given has no unique solution。Warning detected by HPEESOFSIM during TRAN analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X359.L1.i' and `X670.L1.i').
Error detected by HPEESOFSIM during TRAN analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X540.L1.i' and `X982.L1.i').
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X737.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X6334.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X6314.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X344.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X5518.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X650.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X11290.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X635.L1.i.
Error detected by HPEESOFSIM during DC analysis `Tran1'.
No DC convergence.
To search for a more robust convergence algorithm,
set ConvMode=1 on the DC analysis and perform the DC
simulation again.This will cause the simulator to vary
the convergence parameters and report which parameter
setting produces the fastest convergence.Status / Summary
HPEESOFSIM (*) 2003A.300 Apr9 2003 (built: 04/09/03 22:50:55)
Copyright Agilent Technologies, 1989-2003.
...........
Perform Pseudo-Transient analysis
..
Error: Circuit Failes to converge at node `_net350649'
-------------------------------------------------------------------------------
Simulation finished with errors.

当中提到要把ConvMode=1,可是我没有找到在哪里设置这个参数
这个问题比较棘手,望达人赐教
多谢

声明:网友回复良莠不齐,仅供参考。如需更专业系统地学习ADS,可以购买资深专家讲授的ADS最新视频培训课程